Benchmarks

Scorecards

How each control law scores on the Open Benchmark Set, by system and stage, without reading the papers. Every number here comes from the published scorecards.

Pick a system, a stage and a set of structures; the chart and the table follow. Each line is in decibels, and lower or nearer zero is closer. How to read a scorecard.

MIMO Random

Version 0.2doi.org/10.5281/zenodo.24310742About the suite

System
Stage
Structures
Stress error: how far the article's stress on the shakers was from its stress in service, every element counted. Median over structures; the bar spans the middle half. Lower is closer. 0 dB is a perfect match.
Scorecard lines for each law. Column headings sort the table.
SystemStageStructuresFrom
Pseudo-inverse, closed looppinv_closedMore control gauges than shakersStage 1, linearStudy6.586.44−0.25+22.923.693.25 to 4.41−0.34The Six Shipped Laws
Pseudo-inverse, open looppinv_openMore control gauges than shakersStage 1, linearStudy5.935.99−0.95+21.773.393.08 to 3.90−0.64The Six Shipped Laws
Shape-constrainedshape_svdMore control gauges than shakersStage 1, linearStudy7.136.87−2.07+20.924.453.74 to 5.03−2.92The Six Shipped Laws
Buzz-test matchedbuzz_matchMore control gauges than shakersStage 1, linearStudy6.046.28+0.35+23.003.152.99 to 3.69−0.02The Six Shipped Laws
Minimum drivemin_driveMore control gauges than shakersStage 1, linearStudy10.4311.46−3.60+28.178.447.13 to 9.63+5.99The Six Shipped Laws
Band averageband_averageMore control gauges than shakersStage 1, linearStudy4.695.35−0.64+19.403.292.93 to 3.60−1.94The Six Shipped Laws
Pseudo-inverse, closed looppinv_closedMore control gauges than shakersStage 2, realistic sizeStudy6.636.47−0.22+21.893.803.29 to 4.29−0.05The Six Shipped Laws
Pseudo-inverse, open looppinv_openMore control gauges than shakersStage 2, realistic sizeStudy6.146.07−1.23+20.583.693.24 to 4.23−0.65The Six Shipped Laws
Shape-constrainedshape_svdMore control gauges than shakersStage 2, realistic sizeStudy7.026.90−2.19+20.124.033.73 to 5.29−2.64The Six Shipped Laws
Buzz-test matchedbuzz_matchMore control gauges than shakersStage 2, realistic sizeStudy5.966.21+0.38+21.913.443.02 to 3.71+0.44The Six Shipped Laws
Minimum drivemin_driveMore control gauges than shakersStage 2, realistic sizeStudy10.1911.13−3.27+28.148.547.67 to 9.74+6.25The Six Shipped Laws
Band averageband_averageMore control gauges than shakersStage 2, realistic sizeStudy4.685.34−0.75+18.423.073.01 to 3.37−1.37The Six Shipped Laws
Pseudo-inverse, closed looppinv_closedMore control gauges than shakersStage 2, strong sizeStudy6.536.51−0.36+22.094.604.24 to 5.69+1.78The Six Shipped Laws
Pseudo-inverse, open looppinv_openMore control gauges than shakersStage 2, strong sizeStudy6.546.39−1.69+19.174.664.41 to 5.18+0.65The Six Shipped Laws
Shape-constrainedshape_svdMore control gauges than shakersStage 2, strong sizeStudy6.956.81−2.22+19.683.893.43 to 4.41−1.51The Six Shipped Laws
Buzz-test matchedbuzz_matchMore control gauges than shakersStage 2, strong sizeStudy6.096.25+0.37+22.095.314.38 to 5.70+2.80The Six Shipped Laws
Minimum drivemin_driveMore control gauges than shakersStage 2, strong sizeStudy10.8111.31−4.68+28.529.999.10 to 10.30+7.88The Six Shipped Laws
Band averageband_averageMore control gauges than shakersStage 2, strong sizeStudy4.985.42−0.99+18.343.943.65 to 4.28+0.39The Six Shipped Laws
Pseudo-inverse, closed looppinv_closedAs many shakers as control gaugesStage 1, linearStudy3.9210.73+4.24+37.0111.6811.02 to 12.99+11.08The Six Shipped Laws
Pseudo-inverse, open looppinv_openAs many shakers as control gaugesStage 1, linearStudy4.5311.55+5.42+38.8214.2912.55 to 15.90+13.15The Six Shipped Laws
Shape-constrainedshape_svdAs many shakers as control gaugesStage 1, linearStudy6.036.47−0.73+23.063.552.94 to 4.13−1.84The Six Shipped Laws
Buzz-test matchedbuzz_matchAs many shakers as control gaugesStage 1, linearStudy3.9610.77+4.25+37.2611.7110.79 to 13.44+10.94The Six Shipped Laws
Minimum drivemin_driveAs many shakers as control gaugesStage 1, linearStudy3.377.76+1.86+29.156.015.10 to 7.84+4.37The Six Shipped Laws
Band averageband_averageAs many shakers as control gaugesStage 1, linearStudy2.125.53+0.52+22.492.872.65 to 3.58−0.12The Six Shipped Laws
Pseudo-inverse, closed looppinv_closedAs many shakers as control gaugesStage 2, realistic sizeStudy4.949.56+3.74+32.519.948.67 to 10.95+9.06The Six Shipped Laws
Pseudo-inverse, open looppinv_openAs many shakers as control gaugesStage 2, realistic sizeStudy6.8711.90+6.38+38.7614.2412.90 to 15.32+13.31The Six Shipped Laws
Shape-constrainedshape_svdAs many shakers as control gaugesStage 2, realistic sizeStudy6.116.54−0.57+21.143.363.12 to 4.14−1.56The Six Shipped Laws
Buzz-test matchedbuzz_matchAs many shakers as control gaugesStage 2, realistic sizeStudy5.039.77+4.11+34.5410.299.00 to 11.17+9.42The Six Shipped Laws
Minimum drivemin_driveAs many shakers as control gaugesStage 2, realistic sizeStudy4.528.32+2.56+30.237.686.62 to 9.42+5.95The Six Shipped Laws
Band averageband_averageAs many shakers as control gaugesStage 2, realistic sizeStudy1.915.50+0.53+22.323.362.67 to 3.58+0.42The Six Shipped Laws
Pseudo-inverse, closed looppinv_closedAs many shakers as control gaugesStage 2, strong sizeStudy5.488.94+3.41+30.0012.5810.00 to 14.27+11.07The Six Shipped Laws
Pseudo-inverse, open looppinv_openAs many shakers as control gaugesStage 2, strong sizeStudy7.8111.59+6.66+36.9615.1914.13 to 16.16+14.35The Six Shipped Laws
Shape-constrainedshape_svdAs many shakers as control gaugesStage 2, strong sizeStudy6.136.57−0.75+20.344.023.58 to 4.61−0.17The Six Shipped Laws
Buzz-test matchedbuzz_matchAs many shakers as control gaugesStage 2, strong sizeStudy5.709.16+3.80+30.2012.759.90 to 14.19+11.50The Six Shipped Laws
Minimum drivemin_driveAs many shakers as control gaugesStage 2, strong sizeStudy5.509.06+3.60+30.2212.019.96 to 13.32+10.88The Six Shipped Laws
Band averageband_averageAs many shakers as control gaugesStage 2, strong sizeStudy2.055.56+0.20+21.195.763.87 to 6.28+2.11The Six Shipped Laws
Pseudo-inverse, closed looppinv_closedMore control gauges than shakersStage 1, linearHeld back6.656.37+0.03+22.234.033.49 to 4.48−0.27The Six Shipped Laws
Pseudo-inverse, open looppinv_openMore control gauges than shakersStage 1, linearHeld back6.056.07−0.62+20.863.843.18 to 4.23−0.53The Six Shipped Laws
Shape-constrainedshape_svdMore control gauges than shakersStage 1, linearHeld back7.116.71−1.86+20.004.564.20 to 5.32−3.44The Six Shipped Laws
Buzz-test matchedbuzz_matchMore control gauges than shakersStage 1, linearHeld back6.015.97+0.53+20.973.673.07 to 4.06+0.59The Six Shipped Laws
Minimum drivemin_driveMore control gauges than shakersStage 1, linearHeld back10.7111.51−4.13+29.098.257.01 to 8.85+4.90The Six Shipped Laws
Band averageband_averageMore control gauges than shakersStage 1, linearHeld back4.805.32−0.42+19.623.192.82 to 3.94−1.37The Six Shipped Laws
Pseudo-inverse, closed looppinv_closedMore control gauges than shakersStage 2, realistic sizeHeld back6.716.40+0.12+21.594.203.42 to 4.84−0.11The Six Shipped Laws
Pseudo-inverse, open looppinv_openMore control gauges than shakersStage 2, realistic sizeHeld back6.286.19−0.85+20.193.873.32 to 4.63−0.46The Six Shipped Laws
Shape-constrainedshape_svdMore control gauges than shakersStage 2, realistic sizeHeld back6.986.66−1.93+19.454.834.28 to 5.18−3.30The Six Shipped Laws
Buzz-test matchedbuzz_matchMore control gauges than shakersStage 2, realistic sizeHeld back5.995.99+0.49+21.154.093.04 to 4.24+0.82The Six Shipped Laws
Minimum drivemin_driveMore control gauges than shakersStage 2, realistic sizeHeld back11.1411.85−4.46+29.097.857.14 to 8.14+4.91The Six Shipped Laws
Band averageband_averageMore control gauges than shakersStage 2, realistic sizeHeld back4.595.28−0.50+16.813.052.76 to 3.50−0.93The Six Shipped Laws
Pseudo-inverse, closed looppinv_closedMore control gauges than shakersStage 2, strong sizeHeld back6.616.23−0.19+21.854.934.54 to 5.79+1.18The Six Shipped Laws
Pseudo-inverse, open looppinv_openMore control gauges than shakersStage 2, strong sizeHeld back6.656.33−1.48+21.174.874.68 to 5.63+0.18The Six Shipped Laws
Shape-constrainedshape_svdMore control gauges than shakersStage 2, strong sizeHeld back6.916.69−1.98+19.244.573.91 to 5.25−2.51The Six Shipped Laws
Buzz-test matchedbuzz_matchMore control gauges than shakersStage 2, strong sizeHeld back5.985.92+0.41+21.035.173.88 to 5.70+2.04The Six Shipped Laws
Minimum drivemin_driveMore control gauges than shakersStage 2, strong sizeHeld back10.5310.62−4.98+27.809.177.60 to 9.94+5.90The Six Shipped Laws
Band averageband_averageMore control gauges than shakersStage 2, strong sizeHeld back4.755.45−0.73+16.683.983.47 to 4.72−0.13The Six Shipped Laws
Pseudo-inverse, closed looppinv_closedAs many shakers as control gaugesStage 1, linearHeld back4.2411.10+4.56+34.6112.159.92 to 13.14+10.92The Six Shipped Laws
Pseudo-inverse, open looppinv_openAs many shakers as control gaugesStage 1, linearHeld back4.9911.59+5.61+37.2212.3210.55 to 13.31+11.64The Six Shipped Laws
Shape-constrainedshape_svdAs many shakers as control gaugesStage 1, linearHeld back5.956.51−0.97+21.183.753.34 to 4.56−1.98The Six Shipped Laws
Buzz-test matchedbuzz_matchAs many shakers as control gaugesStage 1, linearHeld back4.4911.24+4.65+35.3912.1010.34 to 13.10+11.34The Six Shipped Laws
Minimum drivemin_driveAs many shakers as control gaugesStage 1, linearHeld back3.547.93+1.81+29.315.634.88 to 7.54+4.30The Six Shipped Laws
Band averageband_averageAs many shakers as control gaugesStage 1, linearHeld back1.945.51+0.48+20.873.562.83 to 3.88−0.30The Six Shipped Laws
Pseudo-inverse, closed looppinv_closedAs many shakers as control gaugesStage 2, realistic sizeHeld back5.269.38+3.82+32.969.837.93 to 11.07+8.62The Six Shipped Laws
Pseudo-inverse, open looppinv_openAs many shakers as control gaugesStage 2, realistic sizeHeld back6.4012.00+5.89+35.9612.7111.21 to 14.67+12.01The Six Shipped Laws
Shape-constrainedshape_svdAs many shakers as control gaugesStage 2, realistic sizeHeld back5.806.55−0.99+19.983.893.42 to 4.23−1.94The Six Shipped Laws
Buzz-test matchedbuzz_matchAs many shakers as control gaugesStage 2, realistic sizeHeld back5.5010.06+4.57+30.589.949.21 to 10.99+9.03The Six Shipped Laws
Minimum drivemin_driveAs many shakers as control gaugesStage 2, realistic sizeHeld back4.048.82+2.78+28.468.205.55 to 9.16+6.67The Six Shipped Laws
Band averageband_averageAs many shakers as control gaugesStage 2, realistic sizeHeld back1.585.59+0.54+21.142.922.68 to 3.45+0.03The Six Shipped Laws
Pseudo-inverse, closed looppinv_closedAs many shakers as control gaugesStage 2, strong sizeHeld back5.638.71+3.40+29.1010.8810.07 to 11.43+9.96The Six Shipped Laws
Pseudo-inverse, open looppinv_openAs many shakers as control gaugesStage 2, strong sizeHeld back7.5311.48+6.08+35.4913.8813.01 to 15.83+12.89The Six Shipped Laws
Shape-constrainedshape_svdAs many shakers as control gaugesStage 2, strong sizeHeld back5.716.53−1.00+19.723.943.08 to 5.04−0.61The Six Shipped Laws
Buzz-test matchedbuzz_matchAs many shakers as control gaugesStage 2, strong sizeHeld back5.909.21+3.98+31.2111.3710.53 to 12.16+10.11The Six Shipped Laws
Minimum drivemin_driveAs many shakers as control gaugesStage 2, strong sizeHeld back5.759.25+3.38+30.5410.529.00 to 12.81+9.32The Six Shipped Laws
Band averageband_averageAs many shakers as control gaugesStage 2, strong sizeHeld back1.875.68+0.26+19.624.183.79 to 5.47+1.84The Six Shipped Laws
Independent drivesindependentMore control gauges than shakersStage 1, linearStudy7.286.64+0.67+24.043.242.57 to 4.18+0.09Independent Drive Laws and a Broyden Congruence Law
Nearly independent drivesnearly_independentMore control gauges than shakersStage 1, linearStudy5.896.07+0.81+23.543.152.98 to 3.52+0.30Independent Drive Laws and a Broyden Congruence Law
Broyden congruencebroyden_congruenceMore control gauges than shakersStage 1, linearStudy4.985.62−0.75+17.473.963.32 to 4.09−2.16Independent Drive Laws and a Broyden Congruence Law
Independent drivesindependentMore control gauges than shakersStage 2, realistic sizeStudy7.166.63+0.51+23.373.212.67 to 3.62+0.02Independent Drive Laws and a Broyden Congruence Law
Nearly independent drivesnearly_independentMore control gauges than shakersStage 2, realistic sizeStudy5.946.11+0.83+23.513.252.95 to 3.46+0.74Independent Drive Laws and a Broyden Congruence Law
Broyden congruencebroyden_congruenceMore control gauges than shakersStage 2, realistic sizeStudy4.905.55−0.54+16.873.383.23 to 3.69−1.65Independent Drive Laws and a Broyden Congruence Law
Independent drivesindependentMore control gauges than shakersStage 2, strong sizeStudy7.056.70+0.27+22.933.553.38 to 4.23+1.58Independent Drive Laws and a Broyden Congruence Law
Nearly independent drivesnearly_independentMore control gauges than shakersStage 2, strong sizeStudy6.136.33+0.81+21.124.824.13 to 5.51+2.41Independent Drive Laws and a Broyden Congruence Law
Broyden congruencebroyden_congruenceMore control gauges than shakersStage 2, strong sizeStudy4.945.57−0.50+17.173.853.69 to 4.24+0.56Independent Drive Laws and a Broyden Congruence Law
Independent drivesindependentAs many shakers as control gaugesStage 1, linearStudy5.856.57+1.27+23.913.302.61 to 3.83+0.33Independent Drive Laws and a Broyden Congruence Law
Nearly independent drivesnearly_independentAs many shakers as control gaugesStage 1, linearStudy3.7110.07+3.15+36.5410.5910.19 to 12.29+9.68Independent Drive Laws and a Broyden Congruence Law
Broyden congruencebroyden_congruenceAs many shakers as control gaugesStage 1, linearStudy2.915.70+0.16+21.873.442.83 to 4.10−0.28Independent Drive Laws and a Broyden Congruence Law
Independent drivesindependentAs many shakers as control gaugesStage 2, realistic sizeStudy5.666.47+1.18+23.233.702.76 to 4.18+0.76Independent Drive Laws and a Broyden Congruence Law
Nearly independent drivesnearly_independentAs many shakers as control gaugesStage 2, realistic sizeStudy4.779.28+2.82+31.199.798.52 to 10.12+8.82Independent Drive Laws and a Broyden Congruence Law
Broyden congruencebroyden_congruenceAs many shakers as control gaugesStage 2, realistic sizeStudy2.945.30−0.06+20.153.273.06 to 3.64−0.04Independent Drive Laws and a Broyden Congruence Law
Independent drivesindependentAs many shakers as control gaugesStage 2, strong sizeStudy5.386.58+1.01+21.765.144.08 to 5.83+2.67Independent Drive Laws and a Broyden Congruence Law
Nearly independent drivesnearly_independentAs many shakers as control gaugesStage 2, strong sizeStudy5.668.98+3.01+29.2512.7710.70 to 13.95+11.70Independent Drive Laws and a Broyden Congruence Law
Broyden congruencebroyden_congruenceAs many shakers as control gaugesStage 2, strong sizeStudy2.975.48−0.03+20.235.954.23 to 6.51+3.24Independent Drive Laws and a Broyden Congruence Law
Independent drivesindependentMore control gauges than shakersStage 1, linearHeld back6.836.19+1.05+27.392.552.09 to 2.93+0.36Independent Drive Laws and a Broyden Congruence Law
Nearly independent drivesnearly_independentMore control gauges than shakersStage 1, linearHeld back5.305.57+1.14+21.412.992.91 to 3.29+1.42Independent Drive Laws and a Broyden Congruence Law
Broyden congruencebroyden_congruenceMore control gauges than shakersStage 1, linearHeld back4.655.30−0.39+18.792.672.43 to 3.32−0.92Independent Drive Laws and a Broyden Congruence Law
Independent drivesindependentMore control gauges than shakersStage 2, realistic sizeHeld back6.606.10+0.97+27.642.842.12 to 2.86+0.69Independent Drive Laws and a Broyden Congruence Law
Nearly independent drivesnearly_independentMore control gauges than shakersStage 2, realistic sizeHeld back5.235.57+1.21+21.572.812.73 to 4.47+1.31Independent Drive Laws and a Broyden Congruence Law
Broyden congruencebroyden_congruenceMore control gauges than shakersStage 2, realistic sizeHeld back4.475.13−0.17+20.512.452.42 to 2.90−0.73Independent Drive Laws and a Broyden Congruence Law
Independent drivesindependentMore control gauges than shakersStage 2, strong sizeHeld back6.216.11+0.96+24.673.372.58 to 3.47+0.73Independent Drive Laws and a Broyden Congruence Law
Nearly independent drivesnearly_independentMore control gauges than shakersStage 2, strong sizeHeld back5.075.70+1.26+22.803.533.44 to 4.08+2.46Independent Drive Laws and a Broyden Congruence Law
Broyden congruencebroyden_congruenceMore control gauges than shakersStage 2, strong sizeHeld back4.234.94+0.17+19.663.843.39 to 3.86+1.51Independent Drive Laws and a Broyden Congruence Law
Independent drivesindependentAs many shakers as control gaugesStage 1, linearHeld back5.266.50+1.10+24.113.292.99 to 3.29+0.78Independent Drive Laws and a Broyden Congruence Law
Nearly independent drivesnearly_independentAs many shakers as control gaugesStage 1, linearHeld back3.5310.60+4.81+37.6611.8310.13 to 12.45+10.63Independent Drive Laws and a Broyden Congruence Law
Broyden congruencebroyden_congruenceAs many shakers as control gaugesStage 1, linearHeld back2.817.30+1.22+21.874.203.23 to 5.86+2.98Independent Drive Laws and a Broyden Congruence Law
Independent drivesindependentAs many shakers as control gaugesStage 2, realistic sizeHeld back4.846.42+0.99+22.733.282.58 to 3.53+0.98Independent Drive Laws and a Broyden Congruence Law
Nearly independent drivesnearly_independentAs many shakers as control gaugesStage 2, realistic sizeHeld back4.1910.02+4.48+34.9211.257.85 to 12.22+10.72Independent Drive Laws and a Broyden Congruence Law
Broyden congruencebroyden_congruenceAs many shakers as control gaugesStage 2, realistic sizeHeld back2.796.81+0.99+20.643.492.80 to 5.83+2.34Independent Drive Laws and a Broyden Congruence Law
Independent drivesindependentAs many shakers as control gaugesStage 2, strong sizeHeld back4.516.37+0.61+22.394.694.26 to 4.72+2.52Independent Drive Laws and a Broyden Congruence Law
Nearly independent drivesnearly_independentAs many shakers as control gaugesStage 2, strong sizeHeld back5.189.56+4.08+31.7511.469.23 to 13.58+10.85Independent Drive Laws and a Broyden Congruence Law
Broyden congruencebroyden_congruenceAs many shakers as control gaugesStage 2, strong sizeHeld back2.636.51+0.87+21.117.273.83 to 7.97+6.31Independent Drive Laws and a Broyden Congruence Law

About These Scores: The Six Shipped Laws

Each law at its defaults, closed loop through Hertzforge's own control service on its simulator, on 20 generated structures of five systems. The controller's protective checks were widened so every run completed; at their defaults about nine runs in ten stopped early. The held-back structures were run by an independent audit after the findings were written down. band_average runs on the banded specification, its native form; the others on the full line target.

What They Show

  • With as many shakers as control gauges, the two pseudo-inverse laws and the buzz-test law held their control gauges closely and over-tested the article's stress by about 8 to 11 dB more than the band-average law, on every structure of both sets.
  • At the strong size of stage 2 the stress error rose for five of the six laws on both sets of structures. The rise came with the softening joints; the hardening member alone moved no law's median by more than 0.2 dB with more control gauges than shakers.
  • The control gauges alone do not rank the laws. With as many shakers as control gauges, shape_svd read further from its target at the control gauges than the pseudo-inverse laws, yet came much closer to the article's stress in service. That is why the scorecard carries held-out gauges and the stress.

The study: Six Control Laws for Multi-Shaker Random Vibration: How Each Scores on the Open Benchmark Set. Every scorecard behind these numbers, with the held-back structures and the audit's own record: doi.org/10.5281/zenodo.24310746.

About These Scores: Independent Drive Laws and a Broyden Congruence Law

Three laws added after the first study, each at its defaults, run the same way: closed loop through Hertzforge's own control service on its simulator, on the same five systems, with the protective checks widened. They ran on ten of the 20 study structures (structures 0 to 9), so each median here is over ten structures where the six laws' are over 20; the study compares all nine laws on those ten. The held-back structures are five, run on the 6 x 12 and 6 x 6 systems. All three laws run on the full line target.

What They Show

  • On the linear structures, at the control gauges only the band-average law is lower than the Broyden congruence law by more than 0.2 dB: by 0.5 dB on the 6 x 12 system and 0.8 dB with as many shakers as control gauges. The Broyden law's level is within about 1 dB of the target.
  • The independent drive law has one of the highest errors at the control gauges. Yet with as many shakers as control gauges, on the linear structures, it is 3.0 to 11.3 dB lower at the held-out gauges and in stress than the two pseudo-inverse laws, the buzz-test law and the nearly independent law.
  • Of 280 claims written by a fixed rule and tested on the five held-back structures, 254 held, 18 fell inside 0.2 dB and 8 were not borne out.

The study: Independent Drive Laws and a Broyden Congruence Law for Multi-Shaker Random Vibration: The Laws, Their Build in Hertzforge, and Their Scores on the Open Benchmark Set. Every scorecard behind these numbers, on the study, held-back and tuning structures: doi.org/10.5281/zenodo.24407972.

MIMO Sine

To Come

Several shakers holding an amplitude and a phase at each control gauge through a sweep, a dwell or a stepped sine, on structures whose resonances move with level. The suite is being built. Its scorecards will be shown here, in the same form, when it is released. What it will hold.

MIMO Shock

To Come

Several shakers firing one shock, judged at several control gauges by its waveform or its shock response spectrum, on a jointed structure that softens as it is driven harder. The suite is being built. Its scorecards will be shown here, in the same form, when it is released. What it will hold.

How to Read a Scorecard

Each line is in decibels, and each is a median over the structures a law ran on.

  • Control gauges: how far the gauges the law controls were from their target, band by band, as an RMS. Lower is closer.
  • Held-out gauges: the same at gauges the law never saw, against their response in service. This is the line a law cannot be tuned to directly.
  • Level: the mean of those errors. Positive means the test ran too strong overall, negative too weak; nearer zero is better.
  • Worst over-test: the largest single band over, at any gauge.
  • Stress error: for every element of the article, its stress on the shakers against its stress in service, as an RMS over the elements. This is what the article went through. 0 dB is a perfect match; lower is closer.
  • Stress bias: the mean of the same errors. Positive means the article was stressed harder than in service.

None of it is pass or fail, and there is no overall rank. Differences under about 0.2 dB are not meaningful: the simulator's own step leaves about that much. The headings of the table sort it, by size, nearest zero first.

Adding a Result

Results from anyone are welcome, on any released suite, with or without Hertzforge. A reported result is listed beside the baselines in the same table, with its law, its authors and a link to the article or code that describes it. How to report one.