Benchmarks

MIMO Shock Suite

Several shakers firing one shock, judged at several control gauges, on a structure whose joints change as it is driven harder.

To Come

This suite is being prepared from the structures and testbed that Hertzforge's own shock control laws were developed and audited on. It is not released and has no published scores yet. When it is, its problems will be on their own DOI and its scorecards on Scorecards, in the same form as the MIMO Random suite's.

The Problem

A bolted structure softens as the level rises: its resonances drop and its damping grows. A control law that measures the structure at a low level and then climbs to full level is working from a model that is already wrong when it matters. When the target is a shock response spectrum at every control gauge, small errors in phase between shakers decide whether the pulse passes. That is the problem this suite is built around.

The Tiers

TierWhat It Holds
LinearA fixture plate on several shakers with every joint stuck. The control case: a law that fails here fails everywhere.
RealisticThe same structure with joints that slip a little, losing frequency and gaining damping with amplitude, inside the ranges measured on real bolted joints.
HarshJoints at low preload, in gross slip well below full level, and joints whose slip force changes from pulse to pulse. Beyond the measured data, on purpose.
HardeningA contact that closes as the level rises, alone and after a softening joint.
FramesMore control points than shakers: twelve controls on eight drives. The targets cannot all be reached.
Shaker limitsShakers that clip just above the full-level drive.

What a Run Will Be Scored On

  • the first pulse at each level, where a law is working from its prediction alone;
  • the worst pulse on the way up, because an over-test on the ladder is still an over-test;
  • where the run ends at full level, and how many pulses it took;
  • the duration and polarity of the pulse, which a shock response spectrum alone does not fix;
  • the held-out gauges and the stress, against the article in service, as in every suite.

Where It Comes From

The structures and the testbed that reruns them were built to develop and audit Hertzforge's own shock control laws, including a set that was sealed from the people writing the laws until the laws were frozen. Once a structure is public it is no longer held out, so each version of the suite will add freshly drawn ones.

Already published on this problem:

The laws that ship today and their limits are in the control law catalog and on Known Limits.