hertzforge.io.signalcalc_mat¶
signalcalc_mat
¶
Time histories from SignalCalc's MATLAB export (.mat, version 7.3).
found = hertzforge.import_file('run.mat')
history, table = found['time_data'], found['channel_table']
part = hertzforge.import_file('run.mat', start=120, stop=130,
channels=['A6501- Z', 'Current'])
SignalCalc writes a recorded time history to MATLAB as an HDF5 file (MATLAB's version 7.3) holding, for N channels:
INP_1_DatatoINP_N_Data, one vector of samples per channel, orTimeData, one matrix of samples by N channels;ChanNameandUnit, character matrices with one row per channel, padded with NUL characters;hDelta, the time step in seconds;SensitivityandInputChanNums, one number per channel, andEUType, a code per channel.
INP_k_Data, or column k of TimeData, holds the channel named in
row k of ChanName. It is not the channel whose InputChanNums entry
is k: the input numbers follow the analyzer's wiring and need not be in
row order, and a shaker's current and voltage monitors read by row are
coherent with each other the way a shaker's are, where read by input
number they are two accelerometers. The values are in each channel's
engineering unit, which Unit names; the sensitivity is kept for
reference, not applied.
What is read: one TimeHistory with a record per channel, starting at
0 s, and a ChannelTable with each channel's node, direction, unit,
quantity and sensitivity, its comment holding its name as the file
gives it and its input number. A name that reads as a node and an axis
becomes the record's DOF: optional letters naming the sensor, the node
number, an optional hyphen, then the axis with an optional sign, so
A6002- X and 6002X are 6002X+ and A6002 Y- is 6002Y-. The
hyphen after the node separates it from the axis and is not a sign.
Any other name (Current, Drive Limit) is the record's DOF as it
stands, which tells the channel from the others and matches no node;
the channel table's comment keeps the name either way, for correcting
a node or direction read wrong. A name that is not a node and an axis
and cannot be a DOF either (one that starts with a digit, or an axis
alone) leaves its record's DOF empty, and the import says so. A unit Hertzforge reads is declared,
converting the values to SI; one it does not is left undeclared with
the file's numbers, and the import says so. EUType is not read: no
public description of its codes was found.
start, stop and channels read part of a long export, as for a
Rattlesnake run (rattlesnake.load): the window is inclusive at both
ends on the file's clock, and only the samples it holds are read from
the file: a channel at a time from INP_k_Data, and from TimeData a
block of samples across the channels at a time, since its compressed
chunks each hold every channel.
Refused, each by name: an hDelta that is not one positive time step,
a channel vector that is a matrix or of another length than the rest, a
Unit, Sensitivity or InputChanNums whose count differs from the
names', an INP_k_Data with no row k and a row with no INP_k_Data, a
TimeData with another number of columns than there are names, a
file holding both TimeData and INP_k_Data, and two channels with
one DOF and one quantity, which nothing could tell apart.
A missing sample is kept as NaN and noted, and so is a channel that
never varies (core.channel_health).
save writes a time history back in the INP_k_Data layout, which
this module reads back; whether SignalCalc's own MATLAB import takes it
has not been tested. The format has no start time, so a history that starts
later than 0 s reads back starting at 0 s.
Functions:
| Name | Description |
|---|---|
sniff |
Whether |
load |
A SignalCalc time history export, read as a time history and its |
handles |
Whether |
save |
Write a time history as a SignalCalc time history export, which |
Classes¶
Functions:¶
sniff
¶
Whether path is a SignalCalc time history export: an HDF5 .mat
holding ChanName, Unit, hDelta and TimeData or at least one
INP_<n>_Data. Only the names of the file's variables are read.
load
¶
load(path: str | PathLike, start: float | None = None, stop: float | None = None, channels: Iterable[int | str] | None = None, progress: Callable[[int, int], None] | None = None) -> dict[str, Any]
A SignalCalc time history export, read as a time history and its channel table.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
path
|
str or PathLike
|
The |
required |
start
|
float
|
A window in seconds on the file's clock, which starts at 0; either end open when omitted. |
None
|
stop
|
float
|
A window in seconds on the file's clock, which starts at 0; either end open when omitted. |
None
|
channels
|
iterable of int or str
|
Which channels to read, by 0-based row or by name as the record
is labeled (its DOF, or its name from |
None
|
progress
|
callable
|
Called with |
None
|
Returns:
| Type | Description |
|---|---|
dict
|
'time_data', the |
Raises:
| Type | Description |
|---|---|
ValueError
|
For anything the module docstring lists as refused. |
save
¶
Write a time history as a SignalCalc time history export, which
load reads back.
One INP_k_Data per record, ChanName from each record's label (its
DOF, or its block), Unit naming each record's unit and hDelta
the time step. With unit_system each record is written in that
system's unit for its quantity (g included, since Unit can say g);
without one, as stored, in SI. A record with no units is written as
its numbers with an empty unit. Sensitivity, InputChanNums and
EUType are not written: a time history does not hold them. The
start time is not kept, since the format has no place for one.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
history
|
TimeHistory
|
What to write. |
required |
path
|
str or PathLike
|
Where; |
required |
unit_system
|
UnitSystem
|
The units to write in. |
None
|
Returns:
| Type | Description |
|---|---|
None
|
|
Raises:
| Type | Description |
|---|---|
ValueError
|
When the history is not evenly sampled. |