A Modal Test run opens in the analysis side as every run does: open the run, or its project file, and the run is converted (hertzforge.io.run_convert). This page says what the run becomes, how a roving hammer survey reaches the modal fit, what the impact windows do to the fitted damping, and how a measurement is estimated again.

What A Run Becomes

Each result of the run folder becomes an object in the project, all in one object group named for the run. Every name the converter reads from the folder is in one table, hertzforge.io.modal_run.WIRE.

In the run folder In the project How
table.json Channel Table Each row's node, direction and analysis role, as for every run. The rows the setup's check names as references (the hammer, or each shaker's force gauge, which the station table keeps as monitor rows) are the references.
results/modal_frf modal_frf (Frf) A record per response against each reference of every measurement, at the DOFs the measurement named (node and direction, written 1Z+), in SI from the channel rows' units. Points are numbered from 1, as the operator saw them (the run folder counts them from 0), and measurements from 1. A point measured again replaces the earlier measurement of it. Each record's comment says the estimator, the averages, the measurement and point, the decay check (how far the worst response had decayed by the block's end, and "response not decayed" over the warning), and the windows.
results/modal_frf, excitation roving modal_frf fixed reference (Frf) The same FRFs turned round by reciprocity, every record marked "transposed by reciprocity". Made when the setup's roving channels are reference rows, as a roving hammer survey's hammer is; for a run with no roving plan, when it has more reference DOFs than response DOFs.
results/modal_coherence, array coherence modal_coherence (Coherence), and modal_coherence fixed reference The ordinary coherence of each record (one reference), and turned round as well when the FRFs are.
results/modal_coherence, array multiple_coherence modal_coherence (MultipleCoherence) Each response's multiple coherence (several references). The kind is the one the array names.
results/modal_reference_spectra modal_reference_spectra (Psd) Each measurement's reference autospectra, in SI. With several references, the condition number of their spectral matrix stays in the run record as an array.
streams/inputs, results/modal_frames Measurement k frames (TimeHistory) Each measurement's accepted frames, a record per channel per frame, cut from the stream at each frame line's span (its first frame and length) and labeled hit 1, hit 2 (or frame 1 for a shaker). An impact frame is timed from the trigger, at the setup's pre-trigger sample, so the pre-trigger samples are at negative times; each record's comment carries the hammer's polarity and the hit's checks (the peak, the target's verdict, a tip warning, a force window that cuts the pulse, a double hit's second peak and ratio, the decay check). The frame lines name no measurement: a point's accepted hits are given to its measurements in the order taken, as many to each as it averaged. A measurement replaced by a later one of its point is kept, named "(replaced)".
results/modal_frames, results/modal_outcome, end.json Run Record Every frame line (accepted, rejected and undone, with the reason and the checks) and every measurement line with its decay check, and the outcome (the totals of hits or frames accepted and taken and of points measured and planned, how the test ended, and whether the emergency stop was issued). hertzforge.io.modal_run.findings reads from it, in words, each measurement whose response had not decayed and each double hit.

The streams are not copied whole. One time history per measurement, rather than per frame, keeps a survey of a hundred points at five hits to a hundred objects, and the frames of one measurement share their DOFs and their length, which is what estimating them again needs. Rejected and undone frames stay in the stream and in the frame lines.

The window record travels on the FRF: the run writes the windows once, on the FRF result (and in the setup), and the converter writes them into each record's comment with the force window, the exponential window's time constant, the estimator and the averages, all of which survive a save. A fit reads the time constant back from there. What the run lacked is listed in the run record: points planned but not measured, accepted hits in no finished measurement, hits whose frames a stream cut short does not hold, values that are not finite numbers, a result whose units do not match the channel table (kept as arrays, with the reason). A run ended early, or killed, converts with what it has. A folder written before the decay check and the hammer's polarity were recorded converts as before, with neither said.

The Fixed-Reference Form

A modal fit needs every response against every reference. A roving hammer survey measures the other way round: one or a few fixed accelerometers, each against a force at every point the hammer visits. By reciprocity the motion at j for a force at k equals the motion at k for a force at j, so the set can be turned round: the fixed accelerometer becomes the reference and the hammered points become the responses (hertzforge.core.modal_test.fixed_reference).

This is valid only when every record is a translational motion (acceleration, velocity or displacement) per force, when both DOFs of every record name a direction, and when the structure is linear and reciprocal (symmetric mass, stiffness and damping, as a passive structure is; a spinning, actively controlled or aeroelastically loaded one need not be). The records cannot show the last of these: it is the test's assumption, and each turned record says it was turned. Anything else is refused, with the reason.

A survey taken as several runs merges into one set (Merge), before or after turning.

The Impact Windows

The force window holds one over the pre-trigger and the pulse, from the frame's trigger sample, then falls to zero by a steep half-cosine and stays zero for the rest of the frame. Its width is the pulse allowance after the trigger, given as a fraction of the whole block and counted from the trigger; the fall is a tenth of the width, at least one sample. A window that would run past the block is refused rather than cut short, and a window that removes the pulse is refused with that cause named. The exponential window, w(t) = exp(-t / tau) from the frame's first sample, is applied to the force and every response alike; tau is set from the value the window ends at, tau = -T / ln(end), with T the block's length in time (block / rate). Both are an impact capture's windows: the averaging of a continuous record does not offer them.

The Exponential Window's Damping

An impact response windowed by exp(-t / tau) decays faster by 1 / tau: each mode's pole moves left by exactly 1 / tau, so a fit of the windowed FRF reads a damping ratio high by 1 / (tau omega_n) to first order, where omega_n is the mode's natural frequency in radians per second. A fit published from an FRF estimated with an exponential window notes this on each mode, in the mode's comment: the time constant, the damping it added, and the mode's frequency and damping less it. The fitted values are left as the fit made them, so the shape set still synthesizes the FRF it was fitted to.

The first-order correction, zeta less 1 / (tau omega_n), is for light damping. It can be badly off when the damping is very small and poorly estimated, since the window's share is then most of what was fitted. Capturing more of the decay (a longer frame, a finer line spacing) is better than correcting for a short time constant.

Estimating A Measurement Again

Estimate Again (project.reprocess_modal_test) takes one measurement's frames and estimates its FRFs and coherence again with the estimator (H1, H2 or Hv), the force window on the references, the exponential window on every channel, or a shaker window, the block and the frames chosen. The results are added beside the frames; the run's own FRFs are not changed. A dead reference, a window that removes the pulse, a block longer than the frames, too few frames for the references and frames that are not finite are refused.

References

  • Trethewey, M. W., and Cafeo, J. A. (1992). "Tutorial: Signal Processing Aspects of Structural Impact Testing." International Journal of Analytical and Experimental Modal Analysis 7(2), 129-149. The exponential window (equation 22) and the damping correction (equation 27), with its caution for very light damping.
  • Fladung, W. A. (1997). "Windows Used for Impact Testing." Proceedings of IMAC XV. The force window, and the exponential window applied to the force and the response alike.