Skip to content

Explorer

An Explorer test drives one sine tone that the operator steers by hand: its frequency, its level, a sweep toward either edge of a band, and a stop. Nothing closes a loop. The service measures the response and never corrects the drive from it, so the operator is the loop. The drive is in volts peak at the drive output, from 0 V up to a ceiling the operator gives. While the tone moves, the service keeps the response level at each frequency it has visited, the survey line, from which the operator reads a resonance.

This guide is written for the test engineer running the test. It follows the order of a run: the station and channels, the tone and the drive, the records, then the run itself. Explorer shares its run bar, station panel and channel table with the other test types.

What the Test Does

  1. Start. The station opens at the rate asked, adopts the rate it programs, narrows the band under 0.45 times that rate, and starts the tone at exactly 0 V at the start frequency. Nothing is driven until the operator raises the level, which is why Explorer has no review hold.
  2. Steering. Each steering verb is taken between the service's batches of two blocks and answered within one batch. The answer is what the service adopted: a frequency clamped into the band, a level clamped to the ceiling, a sweep rate clamped to the fastest sweep. The screen shows the answer, never the request.
  3. Measuring. Between batches the service measures every acquired channel: its rms, its display spectrum, the control channel's frequency by its zero crossings, the control channel's derived velocity and displacement, and the survey line.
  4. End. The operator stops the run (the drive ramps down at the drive slew), aborts it, or a protection ends it.

Opening the Test

In Acquire & Control, choose Explorer from the test types, under Specialized. The screen has two steps, Setup and Run. The run bar (where the data comes from, the run's state, the station time, the tone's frequency and drive, any sweep, who holds control, and Stop and Abort once a run is live) stays in view on both. The summary beside every setup section says what the setup holds, what the control service worked out from it, and what is still missing.

Proceed to Run applies the setup (with any channel table edits first) and shows the run. Start opens the station and starts the tone at 0 V, in one step.

Station and Channels

The station panel chooses the simulator or the NI hardware, as for the other test types. The run drives the channel table's one enabled drive row; a table with no drive row or with more than one is refused, since the extra outputs would stay silent. Every other enabled row is acquired, and at least one is needed. The control row is the first enabled control row, else the first enabled input: the survey line, the measured frequency and the derived motion are read from it.

Each row's abort limits (acceleration in g, velocity in in/s, displacement in mil, peak) are the run's: they are checked on every input sample, and a row past one aborts the run at once.

The Tone and the Drive

  • Band: the frequencies the tone may move in, low to high. The top must be under 0.45 times the rate asked. If the station programs a lower rate, the band is narrowed under 0.45 times that rate at start, and the run's log says so.
  • Start at: where the tone stands at start, inside the band.
  • Rate asked of the station: the usual is 8192 Hz. A station may program a nearby rate; the run adopts it, derives every number from it and shows both.
  • Drive ceiling: volts peak at the drive output. There is no default: give the value for your amplifier's input. It is at most 10 V and at most the drive row's range. Every level is clamped to it, and a generated sample over it aborts the run.
  • Drive slew: dB per second, usually 6. Every level change ramps at it, and so does the stop.
  • Frequency slew: octaves per second, usually 1. The fastest sweep is 60 times it, in octaves per minute.
  • FFT size: the display spectra's size, a power of two from 1024 to 16384, usually 4096 (see "Reading the Survey Line").
  • Steering: how far one press moves the tone: the fine and coarse frequency steps in steps an octave (usually 96 and 6, that is 1/96 and 1/6 octave), the fine and coarse level steps in dB (usually 0.5 and 3), and the sweep rate the steering panel starts from. These stay on this screen; the service is told each step as it is taken.

Beside the setup, From the Control Service gives what the service worked out for the selected station: the block and the output lookahead, the pipeline (how many input frames still carry the tone from before a change at the moment it is made), how long a rise from 0 V and a stop take, how long the service waits for a stop, the fastest sweep, the display's line spacing, and how long after a change of frequency the first survey point comes at each edge of the band.

The Level: Volts at the Output

The level is the drive in volts peak at the output, and only that. Nothing measures the response back into the drive: what the article does at a given voltage is the response you read. A level in any other unit is refused.

  • From 0 V the drive steps once to 1% of the level (40 dB under it), then ramps at the drive slew. At 6 dB/s a rise from 0 V takes 6.7 s; at 30 dB/s, 1.3 s.
  • Down to 0 V the drive ramps to 1% of where it was, then steps to 0. The run stays running, quiet, until a level is set again.
  • A step in dB moves the level from the target in force. It needs a level to step from: at 0 V it is refused, and the screen says to set a level in volts first.

A limit on a rising level is passed by the slew times the queue. When the input first shows a limit passed, the drive already written ahead of it (the pipeline, about 83 ms at 12,800 Hz on the NI station) is still on its way. At 6 dB/s that is about 0.5 dB past the limit; at 30 dB/s, about 2.5 dB. Raise the level slowly near a limit, or set the limit lower by that much.

The Frequency

  • A frequency set by hand lands in one frame, without a break in the tone's phase, clamped into the band. Setting a frequency halts a sweep.
  • A downward jump at constant volts. The drive is volts, and on most shakers the displacement for a given voltage grows as the frequency falls. A jump from a high frequency to a low one at the same level can call for much more stroke than the high frequency did. Nothing predicts this: the row's velocity and displacement limits act on the measured response. Lower the level before a large jump down.

Running the Test

Start answers once the tone runs at 0 V. The level card says "Quiet: the tone is at 0 V".

The steering panel, beside the run's pages, steers the tone:

  • Frequency: steps down and up by the fine and coarse steps, and Go to a frequency.
  • Level: steps down and up in dB, Set a level in volts peak, and To 0 V.
  • Sweep: Down or Up at the rate given, from where the tone stands toward that edge of the band. At the edge the tone parks and holds; a sweep never turns by itself. Hold ends the sweep and the tone holds where it is.

Under the panel is the service's answer to the last verb: "Answered 2000.0 Hz, clamped to the band", "Answered 0.500 V pk, clamped to the ceiling", "Sweeping up at 60 oct/min, clamped to the fastest sweep".

Keys. While the steering panel holds the keyboard focus (click it, or move to it with Tab), Left and Right step the frequency and Up and Down the level, by the fine step, or the coarse step with Shift; H holds a sweep. One press is one step: a key held down does not repeat, and no key moves the tone further than one coarse step. The keys do nothing while the focus is anywhere else.

The run bar keeps Hold, Clear Survey (empty the survey line, which fills again as the tone moves), Stop and Abort.

The level card says what the tone is doing: "Quiet: the tone is at 0 V", "Rising to 0.200 V pk", "Holding 251.3 Hz at 0.200 V pk", "Sweeping up at 4 oct/min", "Parked at the top of the band, 2000 Hz", "Stopping: the drive is ramping down". Under it are the frequency and its target, the frequency measured on the control channel, the drive against its target and the ceiling, the control channel's rms, its velocity and displacement (peak over the last analysis pass, marked while the integrators settle), the station time, and the survey's highest point.

The measured frequency is a cross-check of the tone the service commands, read from the control channel over half a second: the time between its first and last rising zero crossings, each placed between its two samples, against the whole periods between them. A steady tone reads to a few parts per million. It reads "Not yet" until a tone at a level above 0 V has held its frequency long enough: the pipeline, then the half-second window, about 0.6 s after a change. The reading then stays until the tone moves, and updates every half second. It counts samples at the rate the service believes, so it cannot show a station running at another rate; a meter on the drive can.

Stop, Abort and Protections

  • Stop is the controlled stop: any sweep ends, the drive ramps to 0 V at the drive slew, then the station stops. At 6 dB/s that takes 6.7 s. Once a stop has begun nothing raises or moves the drive: every steering verb waits and says so. The run ends "Stopped by the Operator".
  • Abort ends the run within one batch, without the ramp; the station takes the drive down with its own short stop. Any connected screen may stop or abort; everything else needs control.
  • A drive slew so slow that its 40 dB stop would outlast the service's stop wait (30 s, so under 1.333 dB/s) is refused at setup.
  • Drive over the ceiling: a generated sample over the ceiling is clipped and the run aborts.
  • Input abort limits: a row past its acceleration, velocity or displacement limit aborts the run.
  • Motion limit: a slower reading of the control row's derived velocity and displacement, once they have settled, past the row's limit ends the run with the controlled stop.
  • Faults: an underrun, a stalled input, a lost device, a scheduling fault or a failure of the service's own loop end the run at once. A stall of the service's loop shows on the run view, with Abort open.
  • Nobody in control: the run goes on unchanged (tone, level, and any sweep, which parks at its edge) for the timeout shown in the run bar's countdown, then takes the controlled stop. A service shutting down does the same.

Station time, not the screen's clock, times everything: the station time on the run bar and the level card, the stop's ramp and the end.

Reading the Survey Line

The Survey page draws the control channel's response level, peak, at each frequency the tone has visited, on a log frequency axis. The line at the tone's frequency marks where the tone is; the thin line marks the survey's highest point, named under the plot and on the level card. That is how a resonance is found: sweep or step across a band and look for the peak.

  • A point is taken once the tone has stood at a frequency for the pipeline, a short guard and three cycles, and never from fewer than three cycles. Low frequencies take longest: about 0.38 s at 20 Hz against about 0.13 s at 250 Hz and up on the NI station at 12,800 Hz.
  • A visit close to an existing point replaces it. The tone passing through a span, by a sweep or a jump, removes every older point inside it, so a second pass over a band shows the second pass.
  • Points are joined by straight lines in log frequency; a jump leaves a straight line across the span it skipped.
  • A swept point is recorded against the frequency the tone had a pipeline earlier. At 30 oct/min that is about 0.04 octave, which matters only where the response changes fast with frequency.

Why a finer FFT gives a finer line. Two points closer together than half the display's line spacing (the rate over the FFT size) count as one visit. At 12,800 Hz an FFT of 4096 gives 3.125 Hz lines and keeps points at least 1.56 Hz apart; 16384 keeps them 0.39 Hz apart, for a sharp resonance. A larger FFT also makes each display spectrum take longer to fill.

The other pages: Spectra (every acquired channel's latest display spectrum), Time (the control channel's most recent samples, on the station's clock) and Readings (the run in numbers). Pages can be added, renamed and opened in a window of their own for another monitor; that window shows the run and keeps Stop and Abort, and the steering stays on the main screen.

What the Run Records

Each run writes a run folder as every recorded control run does (docs/run-folder.md, "What an Explorer Run Saves"): the run folder's name, explorer unless named, under the program's local data folder; when that name is taken, the run gets the next free one, explorer-2, and so on. It holds the configuration as accepted and what it resolved to, the channel table, the station and the rates asked and adopted, the run's log with every steering verb the run took (its station time, the frame it took effect at, what was asked and what was adopted), every acquired input as read and the drive as the device accepted it, the survey line and each channel's last display spectrum at the end, and how the run ended with what it measured. The operator, the article, notes and the specification the run was made to go in with it. The time histories can be left out (Record time histories off in the setup); the rest is always kept.

The folder is written before the station is opened: a data folder that cannot be written refuses the start, and nothing is driven. While the run goes, the screen names the folder; a problem writing it is a notice, and the run goes on. A finished run offers Open in Analysis, which converts the folder and opens its data in the analysis side's Signals workspace, and Copy Folder Path. The survey line and the spectra are magnitudes with no phase, so on the analysis side they stay in the run's record as named arrays; the time histories become signals there.