MIMO Mixed Mode¶
MIMO Mixed Mode plays sine tones and narrowband random on a random floor, on several shakers controlled together. It is Mixed Mode on more than one drive: the floor is MIMO Random's, a full spectral density matrix across the control points; each tone has its own amplitude at every control and, when you state them, its own phases between the controls; each narrowband is the floor raised, or a density added, in a band that stands still, sweeps or follows another part. Every part is judged against its own alarm and abort bands at every control, and one level schedule moves every part by the same dB. The drives are shared: the floor and every tone play through the same drives, and each drive's peak ceiling is a budget they share.
This guide is for a test engineer who has run single-output Mixed Mode and MIMO Random. It covers what the test holds, how to set one up, the parts and the five laws that run them, the shared drive budget and what the screen means by "limiting", what the floor's law is shown on the lines the parts occupy, what the setup refuses and why, and what is not built yet. It shares its station panel, channel table, run bar and control-law panels with the other test types, its floor, identification and gate with MIMO Random (see mimo-random.md), its tones' law with MIMO Sine (see mimo-sine.md), and its parts, schedule, hold and part switches with Mixed Mode (see mixed.md).
Control laws for this test are an open topic. Nobody has settled how a floor law, a tone law and the servo of a narrowband should share several drives, and the module is built for trying laws: the floor and the tones each take a law from the catalog or a law file, and the three rules that join them are choices on the setup, not fixed.
What the Test Holds¶
- A floor. MIMO Random's reference: one spectral density per control at full level, and one coherence and phase between every pair of controls, from breakpoints or from a reference file. Its band, from the lowest breakpoint to the highest, is the test's band.
- Tones. Up to 12. Each stands still, sweeps or follows another part, as in Mixed Mode. Each has a peak amplitude at every control, and either its phases at every control against the first, or none, when the tones' law chooses them.
- Narrowbands. Up to 12. Each has a width (in hertz or as a share of its center) and a statement at every control: either a raise, the floor lifted by so many dB in the band, or an added density, with one coherence between the controls.
- Drives. Up to 8. Each has an rms ceiling on its random part and a peak ceiling on its summed drive, in volts, and may have an rms abort of its own. There is no default for either ceiling: they are your amplifier's input.
The first version runs up to 16 controls, 8 drives and 8 limit channels.
What a Run Does¶
- Arm. The station opens with every drive row as an output and every control and limit row as an input, on one clock. Nothing is driven.
- Identification. MIMO Random's: independent random on every drive at a level under the reference, giving the model from every drive to every control, each control's multiple coherence and the model's condition across the band.
- The gate. Each control's coherence over the band is checked against the coherence gate and the model's condition against its limit. A gate that does not pass holds the run.
- The prediction. From the model, the service predicts what each drive needs at full level for the floor and every tone together, against its ceilings, and forecasts the budget along the schedule. A prediction over a drive's ceiling holds the run.
- Review. The run always waits here, with the identification, the gate and the prediction on screen. With nothing holding it, Proceed goes on. Past a failed gate or a prediction over a ceiling, only Override with your words goes on (the override names the hold, and your words go in the log); an override of the gate goes on to the prediction, which may hold again. A forecast that finds no budget that fits refuses the run, and no override passes it. Or stop.
- The floor alone. The floor engages alone at the first level and plays until it has equalized.
- The parts come in. Parts time starts, and each tone and narrowband whose window is open and that is switched on ramps in over the part ramp.
- Each loop. Each tone is tracked at every control and taken out of the control signal; the floor's law is called on what is left; each narrowband is servoed; the tones' law is called for every tone; the ceiling rule fits the sum to each drive's budget; every part is judged.
- End. The schedule finishes and every part ramps down together, or the run is stopped or aborted, and says why in plain words.
Setting One Up¶
Open Acquire & Control and choose MIMO Mixed Mode under MIMO. The screen opens on Setup, in sections, with a summary beside every section that lists what is left to fix and every refusal and warning the control service gives, by name. The setup is checked by the control service as you edit (a dry run that changes nothing). Proceed to Run applies the setup and shows the run.
Station and Channels¶
The station and channel table are shared with every test type. Every enabled control row is a control unless you switch it off here; every enabled drive row is a drive, in the table's order. Each drive takes its rms ceiling, its peak ceiling (at least the rms ceiling), its peak abort, the most the identification may put on it and, if you want one, its rms abort. The peak abort left empty is the peak ceiling plus 1 dB, and the field shows that value; one you give must be above the peak ceiling.
Floor Reference¶
As MIMO Random's: a breakpoint table for each control, with one coherence and phase for every pair, or a reference file. The reference the service builds is drawn under the tables, and a reference the service had to repair is used only when you accept the repair.
Parts¶
The tones' table and the narrowbands' table, each row a part with its id, name, switch, motion and window, and under it a row for every control:
- A tone: its peak amplitude in g at that control and, when Phases stated is on, its phase in degrees against the first control. A tone's amplitude is a constant at each control; the amplitude-against-frequency profile of single-output Mixed Mode is not offered here yet.
- A narrowband: its raise in dB at that control, or its added density in g²/Hz, with one coherence for the band.
Beside the tables are the tracking bandwidth (usual 0.5 Hz) and the width left out of the floor's average around each standing tone (usual 2 Hz). The panel says how late the tracker reads each tone at the bandwidth given (see "What Is Not Built").
Schedule and Identification¶
The level schedule is Mixed Mode's: levels in dB under full level, each held for its dwell, then full level for its time. The schedule is Automatic (each level held for its dwell) or Manual (the level moves only by hand, to a level of the schedule); the mode can be switched before the run and while it runs. Identification takes its level under the reference, its starting drive, how near the level it must come and in how many steps, its frames and its noise frames; the gate takes the coherence gate and the condition limit. The run always holds for review after identification.
Laws¶
Five choices, each with what it means beside it.
- The floor's law is chosen from the service's list of laws in the MIMO world, the same list MIMO Random offers, with its parameter form. Nothing in the screen names a law: the list is the service's.
- The tones' law is chosen from the service's list in the MIMO sine world, as MIMO Sine offers, with its parameter form. It decides each tone's complex amplitude on every drive.
- The band law: Automatic (one servo per band for a raise, one per control for an added density), One Servo per Band (one gain at every control, keeping the floor's shape between them), or One Servo per Control.
- The ceiling rule, for a drive out of room (see "The Shared Drive Budget"): Common Scale or In Turn.
- The fill rule, for the lines a part occupies (see "What the Floor's Law Sees Under a Part"): No Error or Fill From the Model.
Limits and Protections¶
Limit channels with their ceilings and abort margins, the floor's envelope and divergence aborts (the loops and the dB a divergence is counted from), the loops to settle before the checks, the overload share, the loop's ramps, soft start and caps, and the run record's words.
Prediction and Budget¶
Before identification there is no model, so this section says the prediction comes after it. Once the run has identified, the prediction shows each drive's random rms and peak, the tones' peak sum and the total against its ceilings, each control's predicted levels, and the forecast's nearest approach to a ceiling along the schedule as a bar; a forecast that cannot fit says which drive, when and by how much. Refusals and warnings are listed here by name, each with the part, control, drive or limit channel it concerns where the service names one.
The Shared Drive Budget¶
Every drive plays the floor and every tone at once, so each drive's peak ceiling is one budget for all of them: the floor's peak plus every tone's amplitude on that drive. When a drive would go over its peak ceiling, the ceiling rule decides what gives:
- Common Scale. Every tone is scaled down by the same factor, so the tones keep their proportions between themselves and between the controls. The run card shows the factor ("Tones at 86 %").
- In Turn. Each tone is judged in order against what the others already play, as single-output Mixed Mode does. The last tones lose first, and the outcome depends on the order of the tones.
The floor is never scaled for the tones. While a tone is scaled down, the run is limiting: the header says Limiting, the parts table marks every tone held under its target, and the drives card shows each drive's need against its ceiling and the common scale. A limiting tone is under its target by the factor shown, and its error at every control shows it. Limiting is not a fault: it is the budget doing its work, and the log says each time a drive runs out of room.
What the Floor's Law Sees Under a Part¶
A tone or a servoed narrowband occupies the floor's lines in its band. The floor's law is not shown those lines as measured, because it would chase the part. The fill rule says what it is shown instead:
- No Error. On every occupied line, the floor's law is shown the reference as if measured. It sees no error there, and its drive on those lines stays where it was when the part came in.
- Fill From the Model. On those lines, the floor's law is shown what the model predicts the floor alone would read from the drive in force. Its drive there keeps moving with the model.
What Is Refused and Why¶
The service refuses a setup it cannot run, by name, with the part, control or drive it concerns. The names you may see:
| Refusal | Why |
|---|---|
| Part outside the band | A tone or narrowband leaves the floor's band somewhere in its motion |
| Parts too close | Two tones come within two tracking widths of each other |
| Exclusion under two lines | With tones, the width left out around each tone is less than two of the frame's lines; widen it or lengthen the frame |
| Too many tones, too many narrowbands, controls, drives or limits | Over the first version's counts |
| Two parts with one id, follows an unknown part, follows itself, followers in a loop | The parts list does not hold together |
| Wrong number of values per control | A per-control list does not match the controls |
| Band not additive | A narrowband would take from the floor: a raise under 0 dB, or an added density that is not a valid spectral matrix at some control or line |
| Band as a full matrix: not built | A narrowband stated as a full matrix between the controls |
| Tone law refuses the tone | The chosen tones' law cannot run a tone as stated (for example, phases left to a law that cannot choose them) |
| Budget cannot fit | The forecast needs more than a drive's peak ceiling with every tone at its target |
| Model update: not built | The setup asks for the model to be updated during the run |
| Unknown band law, ceiling rule or fill rule; law not in the catalog | A choice the service does not know |
| Reference not accepted | The floor's reference cannot be used |
A prediction over a ceiling is said at review: you may still override with your words, and the ceiling rule then holds the tones down for the whole run. A forecast that cannot fit is refused at review, and no override passes it.
A sweep faster than the tracker follows is a warning, not a refusal: the part's row says how fast it moves and how late the tracker reads it.
What Is Not Built¶
- Updating the model during the run. The model from identification is held for the whole run;
a setup that asks for it to be updated is refused as
frf_update_not_built. - Narrowbands that take from the floor, and narrowbands as a full matrix. A narrowband must add to the floor at every control; a band stated as a full matrix between the controls is refused.
- Tones that sweep faster than the tracker can follow. Each tone is read through a tracking filter, and at the default 0.5 Hz bandwidth the tracker reads the tone about 1.25 s late (the delay is about 0.625 divided by the bandwidth). Through a resonance a tone's response changes faster than that: a sweep of a few Hz/s moves several hertz in 1.25 s, more than the width of a lightly damped resonance, so the tracker loses the tone and the run aborts. Sweeps of a few Hz/s through a resonance are beyond it. A wider tracking bandwidth shortens the delay but lets more of the floor into each tone's reading.
- A tone amplitude profile against frequency. Each tone's amplitude is constant at each control.
- Changing a law's parameters during the run. Neither the floor's laws nor the tones' laws take parameters while they run; set them in the setup.
- Taking a control out at the gate. The floor, every tone and every narrowband are stated at every control, so a control cannot be dropped once the run has identified. Change the controls in the setup, or override the gate with your words.
- Keeping an identification for a later run. Every run identifies. The record keeps the identification, but it cannot be loaded into another run.
The Run Screen¶
The run card carries the verbs that apply now: Arm, Start, Proceed at review, Override with your words past a failed gate or a prediction over a ceiling, Hold and Resume, the schedule's mode (Automatic or Manual), the level steps and the levels of the schedule in manual, Stop and Abort. At review it gives the identification and its gate in a line and the prediction. Every part's switch is in the parts table; the floor has none.
- The parts table: for every part its id, kind, switch and frequency, whether it is held, whether it is limiting (a tone at its scale, a narrowband held back while its drive is out of room), whether a narrowband is folded into the floor, and at every control its target, its measured value, the error in dB and its alarm. A narrowband is stated in dB against the floor, so it shows its error and no target.
- The drives card: for every drive the random part's rms, the held peak, the tones' sum, the peak played, the headroom left under its peak ceiling (in volts and dB), its peak abort, and the common scale.
- The limits card: for every limit channel how far its worst line is over its ceiling (negative: under) and at what frequency.
- The level card: the level, the schedule's mode, the run's time, the floor's state and loops, and how the run ended.
- The pages: the control spectra with their alarm and abort lines; the residual with the tones taken out, with the cross terms; the cross terms alone; the drives; each tone's amplitude and phase history at every control; each narrowband's level against its statement. The service draws these seven and no others.
- The log: every state, level, hold, part switch, limit, alarm and trip, with your words.
The screen offers no control to change a law's parameters during the run, to take a control out at the gate, or to save or load an identification: the service does not build them (see "What Is Not Built").
What a Run Saves¶
Every run that arms leaves a run folder under the data folder, named
<date>-<time>_mimo_mixed_<run id>. It is written while the run goes and can be read at any
moment. The run is labelled SIM or HARDWARE from the station it ran on.
From the arm:
- The setup as accepted, and what it resolved to: every part as the controller plays it, with its alarm and abort bands at every control. It also holds:
- the floor's reference and where it came from;
- the controls, the drives with their ceilings and aborts, and the limit channels;
- both laws, the band law, and the ceiling and fill rules;
- the gate, the schedule and the full-level time.
- The channel table as it was used.
- Both laws, each with the world it comes from and its parameters. A law that is a file is kept beside the record.
After the identification: the model from every drive to every control and limit channel, each control's coherence, the response and drive spectra, and the identification's own facts: its level, its steps, its frames and its lag.
As the run goes:
- every tone's frequency, its scale under the shared ceiling, and at every control its tracked amplitude, phase, target and error;
- every band's level against its statement at every control;
- every drive's random part, peak, tones' sum and headroom;
- the floor's spectra at each level change and at the end;
- every call of both laws.
The log holds every state, the review's prediction, every override with your words, every level and mode change, and every hold, part switch, alarm, limit and trip. The end says how the run ended and holds every override again. Every input as read and every drive as played are kept as time histories unless the setup switches them off.
Open in Analysis turns the folder into a project:
| In the run folder | In the project |
|---|---|
streams/inputs, streams/drives |
Time histories, in SI |
results/reference |
Specification: the floor's reference, every control's autospectrum and every cross term, with each control's alarm and abort lines |
results/identification_frf |
identification_frf: an FRF of every control against every drive |
results/identification_coherence |
identification_coherence: each control's multiple coherence |
results/identification_response, results/identification_drive |
Spectra of the controls and the drives during the identification, with their cross terms |
results/control_spectra, results/drive_spectra, results/tone_levels, results/band_levels, results/drive_levels, results/control_trace, results/identification, the log and the end |
The Run Record, as named arrays |