Modal Test¶
A Modal Test measures frequency response functions (FRFs) at every point of a structure, for the modal fit. The force comes from an impact hammer with a force gauge, or from one or more shakers driven open loop. Each point is averaged: hits in impact mode, frames in shaker mode. The test estimates each point's FRF and coherence as the averages come in, saves every hit or frame taken with the reason it was kept or rejected, and leaves a run folder that opens in the analysis side, in the modal fit. Before anything is armed, the control service checks the setup against the channel table: the rate, the band, the estimator, the references and responses, and every point's DOFs.
This guide is written for the test engineer running the test. It follows the order of a test: the channels and DOFs, impact testing step by step, shaker testing, the windows, what the test checks and what it does not, what a run saves, and opening the test in the fit. The Modal Test shares its run bar, station panel and channel table with the other test types.
What the Test Does¶
- Check. The control service reads the setup and the channel table's DOFs and checks them together. A setup that fails is refused, with the field and the numbers; a warning is shown but does not stop the test.
- Start. The station opens at the setup's rate. In impact mode no drive row is opened.
- Measure. At each point, every hit (or every frame of the shakers' drive) is checked and counted. Each accepted one goes into the point's average, and the FRF and coherence are drawn as the average builds. When a point has its averages, its FRF and coherence are saved, and you move to the next point.
- End. You end the test with End Test once the points you want are measured, or stop or abort it, or a protection ends it.
Opening the Test¶
In Acquire & Control, choose Modal Test from the test types, under Specialized. The screen has two steps, Setup and Run. The run bar stays in view on both, with the current point and the points measured once the test is live. The summary beside every setup section says what the setup holds, what the control service made of it (the rate, the block, the line spacing, the band, the estimator, the plan and the trigger), every warning and refusal in the service's own words, and what is still left to fix, each a click from its section.
Proceed to Run applies the setup, with any channel table edits first, and shows the Measure screen. Save Setup, Open Setup and Open Setup From Run keep and reopen the setup in the open project, as on every test screen.
Channels and DOFs¶
The station panel and the channel table are shared with the other test types. Each measured row
needs a DOF: a node number and a direction, such as 3 and Z+. The DOFs section shows the
table's input rows with their node, direction and role, and edits them in the table itself; there
is no separate list of DOFs. Each row is one of:
- Reference: the force. In impact mode, the hammer's force gauge, which must be the one reference. In shaker mode, the force gauge of each shaker, one reference a shaker.
- Response: an accelerometer, or any other motion transducer.
- Monitor: recorded, but not used in the FRFs.
- Not used: not part of the test.
The units come from each row's unit in the table (N or lbf for a force, g or m/s² for an acceleration), and the FRFs are saved in them. A row with no node or no direction is refused before the test starts.
Impact Step by Step¶
- Set up the channels. In Station & Channels, add the hammer and the accelerometers, each with its unit and sensitivity. In DOFs, make the hammer row the reference and each accelerometer a response, and give each its node and direction.
- Choose the mode and the acquisition. In Mode & Acquisition, choose Impact, the sample rate, the block (which sets the line spacing), the band, the estimator (H1, H2 or Hv) and the averages: the hits taken at each point.
- Plan the points. In Roving, turn on Rove over points and choose the rows that move.
Rove the hammer row for a roving hammer survey: the accelerometers stay put and the hammer
visits every point. Rove the responses for a roving accelerometer survey. Give the points as a
start, a step and a count, or typed or pasted, a node a line (a direction after the node, such
as
4 Z+, when one row roves). The plan lists every point's DOFs. With roving off, the test measures one point, with the DOFs as the table gives them. - Set the trigger and the checks. In Impact: the trigger level, as a percent of the hammer row's range; the pretrigger, the part of the block kept before the trigger; the holdoff, the blocks after a hit before the next can trigger; the double hit threshold; and the tip warning. Set Hammer polarity to the sign the force gauge reads on impact: the trigger watches the force rising through the level in that sign, and the peak and the double hit are judged in it. Once the setup is checked, the section says in the control service's words what the trigger watches. Choose Automatic or Manual accept, and the windows (see Windows).
- Set a force target, if you want one. Flag each hit against a target peak with a peak and a tolerance in percent. A hit outside it is flagged High or Low with its percent; it is never rejected for that.
- Proceed to Run, then Start. The station opens and the counter shows "0 of 5" at the first point.
- Arm, then hit the structure. Space arms. The screen says Arming until the pre-trigger has filled, then Waiting for Hit: hit only then, since the trigger is live only once a whole pre-trigger is in hand. The test arms again by itself after each hit and hold-off, through Arming each time. Each hit is drawn: the force and the response in time, with the windows over them, and the force spectrum. Its tile says Accepted, Rejected or Waiting, with its peak, its flags and its reason. In automatic mode, an overload or a double hit is rejected and any other hit accepted; in manual mode, each hit waits for you.
- Accept or reject. Press Enter or A to accept the latest hit, Backspace or R to reject it, U to undo the last accepted one. In automatic mode these override the service's verdict on the latest hit until the next one lands. Clear Point takes every accepted hit of the point out at once and opens the point again; it asks first, and the tiles stay, marked undone.
- Move on. When the counter reaches "5 of 5", the point's FRF and coherence are saved. Press the Right arrow for the next point and the Left arrow for the previous one, or click a point in the list. With Move to the next point when a point has its hits on, the test moves on by itself. A point measured again replaces the earlier measurement of it; both are kept in the run folder.
- End the test. End Test ends it once the points you want are measured. Open in Analysis then opens the run in the modal fit.
The keys work wherever the focus is, so you can keep the hammer in one hand. They never fire while a text field has the focus, nor with Ctrl, Cmd or Alt held, nor on a held key's repeats; Enter and Space on a focused button are left to the button. Space arms and disarms the trigger.
Use This Hit as the Target sets the force target from the latest hit's peak, when you have landed one you like.
Every count on the screen (the counter, the tiles, the points measured) is the control service's own: the screen keeps no count of its own. On the simulator, Simulated Hit makes the next hit clean, double or overloaded, to try the checks without a hammer.
The force and response plots show the latest hit's own block, from its first sample, with the windows it was taken with drawn over them: the force window over the force, and the exponential window over both. A double hit's second impact is marked on the force trace where the control service found it, and said in words with its size against the peak. The force spectrum shows how much of the band the tip reaches, with the tip's roll-off, the drop from the spectrum's largest value to its value at the band's top: a drop over the tip warning is flagged, and a harder tip reaches higher. A response that has not died away by the end of the block (its last 5% still over 2% of its loudest, after the windows) is named in the hit's report with how loud it ends; the hit is kept, and a longer block or an exponential window helps. Burst random and burst chirp frames are checked the same way.
Shaker¶
In shaker mode, each shaker plays a broadband source open loop, at its own level in V RMS, on its own drive row. Choose Shaker in Mode & Acquisition. In the Shaker section, add a drive row for each shaker (drive rows are added in Station & Channels), its level, the source and the drive ceiling. On the Measure screen, Start Driving ramps the drive up and averages frames until the point has its averages; the drive then ramps down, 40 dB over 3 s, and goes to zero. Stop Driving part way through a point is a pause: the frames taken stay, and Start Driving goes on with the same average. U takes the latest frame out, and Clear Point every frame of the point.
While the shakers drive, the Measure screen draws the forces, the responses and the drives in time, the reference autospectra, and the FRF with its phase and coherence as the average builds.
| Source | What it plays | Analysis window | Several shakers |
|---|---|---|---|
| Random | A new random record every frame, overlapped by 0, 50 or 75% | Hann | Yes |
| Burst Random | Random for part of each frame (the burst), then silence, so the response dies out inside the frame | None | Yes |
| Pseudo Random | One random frame, repeated | None | No |
| Periodic Random | A new periodic record each frame, played after the delay frames so the response is steady | None | Yes |
| Chirp (Periodic) | A sweep repeated every frame | None | No |
| Burst Chirp | A sweep for part of each frame, then silence | None | No |
A random source is clipped at a crest of 4, so no sample exceeds four times its RMS level; a chirp's crest is a sine's, √2. The check multiplies each level by the source's crest and refuses a level that would reach past the drive ceiling. It refuses a ceiling over the drive row's range.
With several shakers the test refuses:
- Pseudo random. It repeats one frame, so every average sees the same forces. A repeated pseudo-random frame gives a rank-one force matrix, which cannot be inverted to separate the shakers.
- A chirp. The chirps drive one shaker only in this version.
- Too few averages. The averages must be at least twice the number of shakers.
- H2 or Hv. With several references the matrix H1 is used.
Windows¶
The force window, on the hammer's force only, holds one over the pretrigger and the pulse, then falls to zero by a half-cosine and stays zero for the rest of the block. Set its width as a percent of the block after the trigger, and its fall as a percent of the width. A width of 5 to 10% is usual. It keeps the pulse and clears the noise after it. It does not cure a double hit: the second impact lies inside the pulse's own time, and a window short enough to cut it would cut the pulse too. A double hit is rejected and the hit taken again. A hit whose pulse has not fallen before the window ends is flagged.
The exponential window, w(t) = exp(-t/τ), goes on every channel, the force and the responses alike. Set it by the value left at the block's end. It makes a lightly damped response die out inside the block, at a price: it adds damping. Each mode's measured damping ratio is high by 1/(2π f_n τ), where f_n is the mode's natural frequency in Hz. The check warns with the amount at half the band's top frequency, and the run records τ, so the fit can take it out.
The correction (the fitted damping ratio less 1/(2π f_n τ)) is for light damping. It can be badly off when the damping is very small and poorly estimated, since the window's share is then most of what was fitted. A longer block, which captures more of the decay, is better than correcting for a short τ.
In shaker mode there is no force or exponential window: the random source uses a Hann window, and the others need none.
What It Checks¶
Each hit is checked before it is counted:
- Overload. Any channel at 98% of its range or more, with the channel named.
- Double hit. A second impact after the first pulse has fallen below 5% of its peak, judged in the hammer's polarity: a lobe of the force in the hammer's sign whose top is over the threshold and larger than the opposite lobe just before it. The threshold is the larger of the double hit percent of the peak and six times the noise before the trigger, so ringing, an undershoot of the other sign and noise are not double hits. A second impact after the force window still is.
- No response. A response that does not rise well above its level before the trigger is flagged. Without a pretrigger this is not judged, and the check warns.
- Tip. The force spectrum's drop from its largest value to the band's top line, against the tip warning, is flagged.
- Force target. A peak outside the target is flagged High or Low, with its percent. It never rejects.
- Force window. A pulse that has not fallen before the force window ends is flagged.
In automatic mode an overload or a double hit is rejected as it lands; in manual mode every hit waits for you, with these on its tile. The others are flags only, never rejections. The flags are shown as words, and in color. The setup's check also warns when there is no roving plan, when there is one average (the coherence is then 1 at every line and says nothing), and with the exponential window's added damping.
What It Does Not Check¶
- Whether the structure is linear and reciprocal. A roving hammer survey's FRFs are turned round for the fit by reciprocity, which assumes it.
- Whether the DOFs are where the table says they are, or point the way it says.
- Whether the hammer tip suits the band, beyond the tip warning.
- The shakers' attachment, or a force gauge's alignment with the shaker.
- In shaker mode, there is no control loop: each drive plays at its level, whatever the response.
Stop, Abort and Protections¶
- End Test ends the test; in shaker mode, through the stop ramp.
- Stop and Abort are on the run bar, as on every test screen. Abort takes any drive to zero at once.
- In shaker mode, an input row past one of its abort limits, an input overload on a row with abort limits, a sample over the drive ceiling, a drive not made in time and a failure of the drive source end the run with the drive at zero; a failed source zeroes the drive on the very next sample.
- An internal error in the test, or a test that could not begin, ends the run with the emergency stop. The end card says which, and what was kept: every point measured before it.
- Once End Test or Abort is asked, nothing new starts: Arm, Accept, Start Driving and a simulated hit are refused, and the screen says the test is ending.
What a Run Saves¶
Each run writes a run folder under the program's local data folder: the setup as accepted with its
check, the channel table with every DOF, the inputs as the station read them (in shaker mode the
drives as played too), a line for every hit or frame taken and each change of its status, each
point's FRFs, coherence and reference autospectra as it is measured, and how the test ended. The
files and their fields are in docs/run-folder.md, "What a Modal Test Run Saves"; what each
becomes in a project is in docs/modal-test-analysis.md. A test cut off part way keeps every point
finished before it.
Opening the Test in the Fit¶
Open in Analysis, once the test has ended, opens the run in the analysis side's modal fit. The
FRFs are there with their DOFs, coherence and windows, and each measurement's accepted frames as a
time history. A roving hammer survey's FRFs are also turned round by reciprocity into the fixed
reference form a modal fit needs, each record marked so. A fit of FRFs taken with the exponential
window notes the added damping on each mode (see docs/modal-test-analysis.md, "The Exponential
Window's Damping").
Estimate Again estimates one measurement's FRFs and coherence again from its saved frames, with another estimator, other windows, or other frames. The results are added beside the frames; the run's own FRFs are not changed.
References¶
- Trethewey, M. W., and Cafeo, J. A. (1992). "Tutorial: Signal Processing Aspects of Structural Impact Testing." International Journal of Analytical and Experimental Modal Analysis 7(2), 129-149. The exponential window (equation 22) and the damping correction (equation 27), with its caution for very light damping.
- Fladung, W. A. (1997). "Windows Used for Impact Testing." Proceedings of IMAC XV. The force window of 5 to 10% with a cosine taper, and the exponential window applied to the force and the response alike.
- Avitabile, P. (2002). "Modal Space: Which window is most appropriate for the different types of modal tests performed?" Experimental Techniques, February 2002. The force window of about 10%, never to be used to remove a double impact; burst random, of 50 to 80% of the frame, needing no window.